    The Clinical Rationale for the Sentry Bioconvertible Inferior Vena Cava Filter for the Prevention of Pulmonary Embolism

    Get PDF
    The Sentry inferior vena cava (IVC) filter is designed to provide temporary protection against pulmonary embolism (PE) during transient high-risk periods and then to bioconvert after 60 days after implantation. At the time of bioconversion, the device's nitinol arms retract from the filtering position into the caval wall. Subsequently, the stable stent-like nitinol frame is endothelialized. The Sentry bioconvertible IVC filter has been evaluated in a multicenter investigational-device-exemption pivotal trial (NCT01975090) of 129 patients with documented deep vein thrombosis (DVT) or PE, or at temporary risk of developing DVT or PE, and with contraindications to anticoagulation. Successful filter conversion was observed in 95.7% of patients at 6 months (110/115) and 96.4% at 12 months (106/110). Through 12 months, there were no cases of symptomatic PE. The rationale for development of the Sentry bioconvertible device includes the following considerations: (1) the period of highest risk of PE for the vast majority of patients occurs within the first 60 days after an index event, with most of the PEs occurring in the first 30 days; (2) the design of retrievable IVC filters to support their removal after a transitory high-PE-risk period has, in practice, been associated with insecure filter dynamics and time-dependent complications including tilting, fracture, embolization, migration, and IVC perforation; (3) most retrievable IVC filters are placed for temporary protection, but for a variety of reasons they are not removed in any more than half of implanted patients, and when removal is attempted, the procedure is not always successful even with advanced techniques; and (4) analysis of Medicare hospital data suggests that payment for the retrieval procedure does not routinely compensate for expense. The Sentry device is not intended for removal after bioconversion. In initial clinical use, complications have been limited. Long-term results for the Sentry bioconvertible IVC filter are anticipated soon

    Aortic dissection: Percutaneous management of ischemic complications with endovascular stents and balloon fenestration

    Get PDF
    AbstractPurpose: The purpose of this study was to evaluate endovascular stenting (EVS) and balloon fenestration (BF) of intimal flaps for the management of lower extremity, renal, and visceral ischemia in acute or chronic aortic dissection.Methods: Twenty-two patients (16 male, 6 female) with a median age of 53 years (range 35 to 77 years) underwent percutaneous treatment for peripheral ischemic complications of 12 type A (five acute, seven chronic) and 10 type B (nine acute, one chronic) aortic dissections.Results: Ten patients had leg ischemia, 13 had renal ischemia, and 6 had visceral ischemia. Sixteen patients were treated with EVS including 11 with renal, 6 with lower extremity, 2 with superior mesenteric artery, and 2 with aortic stents. Three patients had BF of the intimal flap, and three had BF in combination with EVS. Revascularization with clinical success was achieved in all 22 patients. Two patients died 3 days and 13.4 months after the procedure was performed, respectively. Of the remaining 20 patients, 1 is lost to follow-up, and 19 have persistent relief of clinical symptoms. Mean follow-up time is 13.7 months (range 1.1 to 46.5 months). One case was complicated by guidewire-induced perinephric hematoma.Conclusion: EVS and BF provide a safe and effective percutaneous method for managing peripheral ischemic complications of aortic dissection. (J VASC SURG 1996;23:241-53.

    Fluid Flows of Mixed Regimes in Porous Media

    Full text link
    In porous media, there are three known regimes of fluid flows, namely, pre-Darcy, Darcy and post-Darcy. Because of their different natures, these are usually treated separately in literature. To study complex flows when all three regimes may be present in different portions of a same domain, we use a single equation of motion to unify them. Several scenarios and models are then considered for slightly compressible fluids. A nonlinear parabolic equation for the pressure is derived, which is degenerate when the pressure gradient is either small or large. We estimate the pressure and its gradient for all time in terms of initial and boundary data. We also obtain their particular bounds for large time which depend on the asymptotic behavior of the boundary data but not on the initial one. Moreover, the continuous dependence of the solutions on initial and boundary data, and the structural stability for the equation are established.Comment: 33 page

    New calculations and measurements of the Coulomb cross-section for the production of direct electron pairs by high energy nuclei

    Get PDF
    Recently, new calculations were made of the direct Coulomb pair cross section that rely less in arbitrary parameters. More accurate calculations of the cross section down to low pair energies were made. New measurements of the total direct electron pair yield, and the energy and angular distribution of the electron pairs in emulsion were made for O-16 at 60 and 200 GeV/amu at S-32 at 200 GeV/amu which give satisfactory agreement with the new calculations. These calculations and measurements are presented along with previous accelerator measurements made of this effect during the last 40 years. The microscope scanning criteria used to identify the direct electron pairs is described. Prospects for application of the pair method to cosmic ray energy measurements in the region 10 (exp 13) to 10 (exp 15) eV/amu are discussed

    Spatially varying fractional flow in radial CO 2

    Full text link

    High-efficiency endovascular gene delivery via therapeutic ultrasound

    Get PDF
    AbstractOBJECTIVESWe studied enhancement of local gene delivery to the arterial wall by using an endovascular catheter ultrasound (US).BACKGROUNDUltrasound exposure is standard for enhancement of in vitro gene delivery. We postulate that in vivo endovascular applications can be safely developed.METHODSWe used a rabbit model of arterial mechanical overdilation injury. After arterial overdilation, US catheters were introduced in bilateral rabbit femoral arteries and perfused with plasmid- or adenovirus-expressing blue fluorescent protein (BFP) or phosphate buffered saline. One side received endovascular US (2 MHz, 50 W/cm2, 16 min), and the contralateral artery did not.RESULTSRelative to controls, US exposure enhanced BFP expression measured via fluorescence 12-fold for plasmid (1,502.1 ± 927.3 vs. 18,053.9 ± 11,612 μm2, p < 0.05) and 19-fold for adenovirus (877.1 ± 577.7 vs. 17,213.15 ± 3,892 μm2, p < 0.05) while increasing cell death for the adenovirus group only (26 ± 5.78% vs. 13 ± 2.55%, p < 0.012).CONCLUSIONSEndovascular US enhanced vascular gene delivery and increased the efficiency of nonviral platforms to levels previously attained only by adenoviral strategies

    New statistical method identifies cytokines that distinguish stool microbiomes.

    Get PDF
    Regressing an outcome or dependent variable onto a set of input or independent variables allows the analyst to measure associations between the two so that changes in the outcome can be described by and predicted by changes in the inputs. While there are many ways of doing this in classical statistics, where the dependent variable has certain properties (e.g., a scalar, survival time, count), little progress on regression where the dependent variable are microbiome taxa counts has been made that do not impose extremely strict conditions on the data. In this paper, we propose and apply a new regression model combining the Dirichlet-multinomial distribution with recursive partitioning providing a fully non-parametric regression model. This model, called DM-RPart, is applied to cytokine data and microbiome taxa count data and is applicable to any microbiome taxa count/metadata, is automatically fit, and intuitively interpretable. This is a model which can be applied to any microbiome or other compositional data and software (R package HMP) available through the R CRAN website

    One-Year Analysis of the Prospective Multicenter SENTRY Clinical Trial: Safety and Effectiveness of the Novate Sentry Bioconvertible Inferior Vena Cava Filter

    Get PDF
    Purpose To prospectively assess the Sentry bioconvertible inferior vena cava (IVC) filter in patients requiring temporary protection against pulmonary embolism (PE). Materials and Methods At 23 sites, 129 patients with documented deep vein thrombosis (DVT) or PE, or at temporary risk of developing DVT or PE, unable to use anticoagulation were enrolled. The primary end point was clinical success, including successful filter deployment, freedom from new symptomatic PE through 60 days before filter bioconversion, and 6-month freedom from filter-related complications. Patients were monitored by means of radiography, computerized tomography (CT), and CT venography to assess filtering configuration through 60 days, filter bioconversion, and incidence of PE and filter-related complications through 12 months. Results Clinical success was achieved in 111 of 114 evaluable patients (97.4%, 95% confidence interval [CI] 92.5%–99.1%). The rate of freedom from new symptomatic PE through 60 days was 100% (n = 129, 95% CI 97.1%–100.0%), and there were no cases of PE through 12 months for either therapeutic or prophylactic indications. Two patients (1.6%) developed symptomatic caval thrombosis during the first month; neither experienced recurrence after successful interventions. There was no filter tilting, migration, embolization, fracture, or caval perforation by the filter, and no filter-related death through 12 months. Filter bioconversion was successful for 95.7% (110/115) at 6 months and for 96.4% (106/110) at 12 months. Conclusions The Sentry IVC filter provided safe and effective protection against PE, with a high rate of intended bioconversion and a low rate of device-related complications, through 12 months of imaging-intense follow-up

    Primary recovery factor as a function of production rate: implications for conventional reservoirs with different drive mechanisms

    Get PDF
    This study evaluates the dependency of production rate on the recovery of hydrocarbon from conventional reservoirs using MBAL simulator. The results indicated that the recoveries are sensitive to the production rate in almost all hydrocarbon reservoirs. It was also found that the recovery of volumetric gas drive reservoirs is not impacted by the production rate. In fact, any increase in the production rate improves gas recovery in weak and strong water drive reservoirs. Moreover, increasing the production rate in oil reservoirs decreases the recovery with a significant effect observed in the weak water drive reservoirs. The results of this study demonstrate the need for implementing an effective reservoir management in order to obtain a maximum recovery
    • …